UV-Vis. Double Beam Spectrophotometer-LMSPUV1928

The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy.

Lamp Selection enables conserving the life of D2 & Tungsten lamps. Real time clock for date & time stamping of results.

LIGHT PATH DESIGN: DOUBLE BEAM

LMSPUV1900 double light design can prevent circuit fluctuation and stray light to ensure stability of the instrument.

LONG PATH LIGHT DESIGN

LMSPUV1900 unique 520mm long light path design greatly improved resolution and the bandwidth can reach 0.5nm.

16MM OPTICAL BASE

LMSPUV1900 series use a rigid 16mm diecast aluminum base as their optical mount to ensure the stability and reliability.

6 INCHES LCD DISPLAY

LMSPUV1900 series have a 6 inches LCD display to show results and curves directly on the screen.

SOFTWARE FUNCTIONS

Multi functions operated directly on the spectrophotometer and display the test results’ curve and data wavelength scanning, standard curve, kinetics, multi wavelength scanning, DNA/protein test.

PERFECT CALIBRATION SYSTEM

All baseline, wavelength, dark current can be calibrated automatically to keep good running conditions.

DATA OUTPUT

LMSPUV1900 series are equipped with USB port to connect with a PC

Specifications:

Model LMSPUV1900 LMSPUV1908 LMSPUV1920 LMSPUV1928
Sample Cell Holder 1Omm Cell Holder 8ceII holder programable1Omm 1Omm Cell Holder 8ceII holder programable 1Omm
Bandwidth 1nm 1.0, 2.0, 4.0 nm (variable)
Reference Cell Holder 10 Cell Holder
Make LABMAN
Optical System Double Beam(1200 Lines/mm Grating)
Wavelength Range 190-1100nm
Bandwidth 1nm
Wavelength Accuracy +0.3nm
Wavelength Repeatability +0.2nm
Scanning Speed Fast, Medium & Low
Photometric Accuracy +0.3%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A,0-200%T,0-9999C
Stability + 0.001A/h @ 500nm
Baseline Flatness + 0.001A/h
Noise
+ 0.001A/h

Stray Light <0.05%T @ 220nm,360nm
Data Output Port USB
Printer Port Parallel Port
Display LCD
Light Source D2 Lamp & Tungsten Halogen Lamp (W Lamp)
Detector Silicon Photodiode





The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy.

Lamp Selection enables conserving the life of D2 & Tungsten lamps. Real time clock for date & time stamping of results.

LIGHT PATH DESIGN: DOUBLE BEAM

LMSPUV1900 double light design can prevent circuit fluctuation and stray light to ensure stability of the instrument.

LONG PATH LIGHT DESIGN

LMSPUV1900 unique 520mm long light path design greatly improved resolution and the bandwidth can reach 0.5nm.

16MM OPTICAL BASE

LMSPUV1900 series use a rigid 16mm diecast aluminum base as their optical mount to ensure the stability and reliability.

6 INCHES LCD DISPLAY

LMSPUV1900 series have a 6 inches LCD display to show results and curves directly on the screen.

SOFTWARE FUNCTIONS

Multi functions operated directly on the spectrophotometer and display the test results’ curve and data wavelength scanning, standard curve, kinetics, multi wavelength scanning, DNA/protein test.

PERFECT CALIBRATION SYSTEM

All baseline, wavelength, dark current can be calibrated automatically to keep good running conditions.

DATA OUTPUT

LMSPUV1900 series are equipped with USB port to connect with a PC

Specifications:

Model LMSPUV1900 LMSPUV1908                            LMSPUV1920                          LMSPUV1928
Sample Cell Holder 1Omm Cell Holder 8ceII holder programable1Omm              1Omm Cell Holder        8ceII holder programable 1Omm
Bandwidth                                                                    1nm                              1.0, 2.0, 4.0 nm (variable)
Reference Cell Holder   10 Cell Holder
Make   LABMAN
Optical System   Double Beam(1200 Lines/mm Grating)
Wavelength Range   190-1100nm
Bandwidth   1nm
Wavelength Accuracy   +0.3nm
Wavelength Repeatability   +0.2nm
Scanning Speed   Fast, Medium & Low
Photometric Accuracy   +0.3%T
Photometric Repeatability   0.2%T
Photometric Range   -0.3-3A,0-200%T,0-9999C
Stability   + 0.001A/h @ 500nm
Baseline Flatness   + 0.001A/h
Noise   + 0.001A/h
Stray Light   <0.05%T @ 220nm,360nm
Data Output Port   USB
Printer Port   Parallel Port
Display   LCD
Light Source   D2 Lamp & Tungsten Halogen Lamp (W Lamp)
Detector   Silicon Photodiode

 

Custome

Advantages

    Product Details

    UV-Vis. Double Beam Spectrophotometer-LMSPUV1928


    Product Specifications

    Shipping & Packaging

    Review this product

    Share your thoughts with other customers

    Reviews (0)

    Reviews

    There are no reviews yet.

    Be the first to review “UV-Vis. Double Beam Spectrophotometer-LMSPUV1928”

    Your email address will not be published.